CrystalDiskInfo 5.1.0 (C) 2008-2012 hiyohiyo
Crystal Dew World : http://crystalmark.info/
----------------------------------------------------------------------------
OS : Windows 7 Ultimate Edition SP1 [6.1 Build 7601] (x64)
Date : 2013/03/07 13:55:51
-- Controller Map ----------------------------------------------------------
+ Intel(R) 5 Series/3400 Series Chipset Family 4 Port SATA AHCI Controller - 3B29 [ATA]
+ ATA Channel 0 (0)
- TOSHIBA MK5076GSX ATA Device
-- Disk List ---------------------------------------------------------------
(1) TOSHIBA MK5076GSX : 500,1 GB [0/0/0, pd1]
----------------------------------------------------------------------------
(1) TOSHIBA MK5076GSX
----------------------------------------------------------------------------
Model : TOSHIBA MK5076GSX
Firmware : GS001A
Serial Number : 32VGF2OZS
Disk Size : 500,1 GB (8,4/137,4/500,1)
Buffer Size : 8192 KB
Queue Depth : 32
# of Sectors : 976773168
Rotation Rate : 5400 RPM
Interface : Serial ATA
Major Version : ATA8-ACS
Minor Version : ----
Transfer Mode : SATA/300
Power On Hours : 89 hours
Power On Count : 96 count
Temparature : 40 C (104 F)
Health Status : Good
Features : S.M.A.R.T., APM, 48bit LBA, NCQ
APM Level : 0080h [ON]
AAM Level : ----
-- S.M.A.R.T. --------------------------------------------------------------
ID Cur Wor Thr RawValues(6) Attribute Name
01 100 100 _50 000000000000 Read Error Rate
02 100 100 _50 000000000000 Throughput Performance
03 100 100 __1 0000000002C7 Spin-Up Time
04 100 100 __0 00000000027F Start/Stop Count
05 100 100 _50 000000000000 Reallocated Sectors Count
07 100 100 _50 000000000000 Seek Error Rate
08 100 100 _50 000000000000 Seek Time Performance
09 100 100 __0 000000000059 Power-On Hours
0A 112 100 _30 000000000000 Spin Retry Count
0C 100 100 __0 000000000060 Power Cycle Count
BF 100 100 __0 000000000002 G-Sense Error Rate
C0 100 100 __0 000000000000 Power-off Retract Count
C1 100 100 __0 000000000663 Load/Unload Cycle Count
C2 100 100 __0 002D00100028 Temperature
C4 100 100 __0 000000000000 Reallocation Event Count
C5 100 100 __0 000000000000 Current Pending Sector Count
C6 100 100 __0 000000000000 Uncorrectable Sector Count
C7 200 200 __0 000000000000 UltraDMA CRC Error Count
DC 100 100 __0 000000003046 Disk Shift
DE 100 100 __0 000000000032 Loaded Hours
DF 100 100 __0 000000000000 Load/Unload Retry Count
E0 100 100 __0 000000000000 Load Friction
E2 100 100 __0 0000000000DD Load 'In'-time
F0 100 100 __1 000000000000 Head Flying Hours
WiiBoy escribió:191/BF G-sense error rate Frecuencia de errores como resultado de impactos internos.
Más información en http://www.emezeta.com/articulos/disco- ... z2MrHkYAi6
Supongo que abra sido por algun movimiento brusco del portatil
WiiBoy escribió:yo entiendo que fue pasajero sino te diria que el estado del disco es malo